LiFePO4 for solar and off-grid systems

Off-grid sizing is a loop: daily load decides the bank, the bank decides the array, and the array has to refill the bank on the worst realistic day.

12V · 24V 100Ah – 314Ah Sizing guidance IP65 · Smart BMS
Start with the load

What this system actually powers

LiFePO4 is a good fit for daily cycling because 80% depth of discharge is usable and cycle life is long. The two failure modes to design out are charging below freezing and undersizing the array for cloudy days.

  • Fridge/freezer, lights, fans, water pump — the daily base load.
  • Inverter for tools, microwave or a workshop — check surge.
  • Starlink/router/monitoring — small but 24/7.
  • Seasonal loads: heaters, dehumidifiers, grow lights.

Solar & off-grid

Sizing rule: daily Wh first, then autonomy, then the model.

Sizing

Three steps to the right bank

The arithmetic is simple; the mistakes come from using running watts instead of surge, or Ah without the voltage.

01

1. Daily kWh, then autonomy

A cabin with a fridge, lights and Starlink often uses 1.5–2.5 kWh/day. Two to three days of autonomy is common for off-grid; three days is safer if winter sun is weak.

02

2. Size the bank at 80% DOD

Required Wh = daily Wh × autonomy ÷ (0.8 × inverter efficiency). Then divide by system voltage for Ah. Round up to the next model or parallel count.

03

3. Size the array to refill

Plan for 3–4 kWh of PV per kWh of daily load in good sun, more in winter or high latitudes. Use an MPPT controller with a LiFePO4 profile and leave headroom for cold-weather Voc rise.

Worked example

Example: 2,000 Wh/day, 2 days, 24V. Required ≈ 2,000 × 2 ÷ (0.8 × 0.85) = 5,882 Wh, or about 230Ah at 25.6V. One 24V 200Ah (5,120Wh) is close; two in parallel (10,240Wh) gives real autonomy. A 12V 314Ah pair in series is another route.

Assumes 80% depth of discharge and 85% inverter efficiency. Cold weather, ageing and higher inverter losses need extra margin.

Which model

Models that fit this application

Start with the smallest pack that covers the load, then check the bay and the inverter surge.

12V 314Ah

4019 Wh

Three times the capacity of the 100 Ah pack in one box — fewer parallel connections and a 200 A BMS.

Best for: Full-time vans, larger 12V banks, long runtime without recharging.

Bank limit: 4S4P

View specifications

24V 200Ah

5120 Wh

The largest pack we list today: 5.1 kWh in one 24V case, parallel up to 1S4P.

Best for: Home backup, larger 24V house banks, multi-day off-grid loads.

Bank limit: 1S4P

View specifications

12V 100Ah

1280 Wh

The everyday 12V pack. Light enough to swap by hand, with 100 A continuous output and 4S4P expansion.

Best for: Weekend RVs, camper vans, 12V fridges, small boat electronics.

Bank limit: 4S4P

View specifications

Not sure? Use the sizing calculator, or send us the load list and we will check it.

Open the sizing calculator

Install notes

Before you connect it

FAQ

Questions we get about this application

How many solar panels do I need?
Start from daily kWh, not panel count. A rough planning figure is 3–4 kWh of PV per kWh/day in good sun, with more in winter. Actual yield depends on latitude, tilt, shading and controller efficiency; use a local PV calculator before ordering.
Can I expand the bank later?
Yes, within the limits: 12V models up to 4S4P, 24V models up to 1S4P. Add the same model and similar age, and bring the new battery to a similar state of charge before paralleling.
What happens in winter when it is below freezing?
Discharging is allowed down to −20 ± 5°C, but charging stops at 0 ± 5°C. Keep the battery in a space above freezing, or warm it before charging; these models do not have self-heating.

See all FAQs

Send us the load list — we will size the bank

Include the application, daily runtime, inverter size and destination market. We will reply with a model recommendation and the matching datasheet.