Key takeaways
  • Read the event in the app before you reconnect anything.
  • Remove the load or charger, wait, then reconnect — do not force it.
  • A 0V pack needs a compatible charger; never jump-start it.
  • Repeated trips under the same load mean the bank or wiring is undersized.

1. The five protections

ProtectionTypical causeWhat to do
Over-voltageCharger profile too high, or a cell out of balanceStop charging; check charger voltage; let it rest
Under-voltageLoad left on, or battery run too lowRemove load; recharge with a LiFePO4 charger
Over-currentInverter surge or a shortRemove load; check cables and inverter size
Short circuitWiring fault or reversed polarityStop; inspect wiring before reconnecting
TemperatureCharging below 0°C or over-temperatureLet it return to a safe temperature

2. Recovery steps

  • Switch off the load and the charger. Do not repeatedly reconnect to “test” it.
  • Read the protection event in the app: voltage, current and temperature at the time.
  • Wait one or two minutes for the BMS to reset.
  • Reconnect a compatible charger for an under-voltage event; reconnect the load only after the voltage recovers.
  • If the pack stays at 0V, or the same event repeats immediately, stop and contact support.
Do not jump-start, short the terminals or open the case. Those can bypass the protection that just saved the cells.

3. Why it keeps happening

If the BMS trips every time you run the inverter, the load is probably above the pack’s continuous rating or the cable is too thin. Check the inverter’s surge and the battery’s continuous current before blaming the BMS.

4. What the app can tell you

The app shows state of charge, pack voltage, current, cell voltages, cell spread, temperature and a timeline of protection events. Save or screenshot the event before you change the wiring — it is the best evidence for support.

Common questions

The battery shows 0V. Is it dead?
Not necessarily. The BMS may have disconnected on under-voltage. Remove all loads and try a compatible LiFePO4 charger; if it still will not wake, contact support. Do not jump-start it.
Why does it shut off only when the inverter starts?
That is usually over-current or a voltage dip during the surge. Check the inverter’s peak rating, the battery’s continuous current and the cable size; a thin or long cable makes the dip worse.

Models mentioned

12V 100Ah

1280 Wh

The everyday 12V pack. Light enough to swap by hand, with 100 A continuous output and 4S4P expansion.

12V 314Ah

4019 Wh

Three times the capacity of the 100 Ah pack in one box — fewer parallel connections and a 200 A BMS.

24V 100Ah

2560 Wh

A native 25.6 V pack: half the current of a 12V pack at the same power, fewer inter-battery links.

24V 200Ah

5120 Wh

The largest pack we list today: 5.1 kWh in one 24V case, parallel up to 1S4P.

Compare all models